Call Us+919315340602
10% off on Your First Purchase
Diesel boiler

Diesel boiler

170000 INR/Number

Product Details:

  • Life Span 15 Years
  • Fuel Consumption 10-12 liters/hour
  • Condition New
  • Voltage 415 V
  • Pressure 10.54 kg/cm
  • Heat Efficiency 85%
  • Output Steam
  • Click to view more
X

Diesel boiler Price And Quantity

  • 1 Number
  • 150000.00 - 255000.00 INR/Number
  • 170000 INR/Number

Diesel boiler Product Specifications

  • 415 V
  • Mild Steel
  • 2500 x 1500 x 1600 mm
  • 10.54 kg/cm
  • Boiler
  • 15 Years
  • New
  • 10-12 liters/hour
  • 180C
  • Diesel
  • Horizontal
  • 1000 kg/hr
  • Steam
  • 85%
  • Generation of steam through diesel combustion

Diesel boiler Trade Information

  • 10-15 Days
  • Delhi, Haryana, Jammu and Kashmir, Rajasthan, Uttar Pradesh

Product Description

We are one of the most innovative and renowed manufaturer of diesel boiler


A boiler is an enclosed vessel that provides a means for combustion heat to be transferred into water until it becomes heated water or steam. The hot water or steam under pressure is then usable for transferring the heat to a process. Water is a useful and cheap medium for transferring heat to a process.



The boiler system comprises of: feed water system, steam system and fuel system. The feed water system provides water to the boiler and regulates it automatically to meet the steam demand. Various valves provide access for maintenance and repair. The steam system collects and controls the steam produced in the boiler. Steam is directed through a piping system to the point of use. Throughout the system, steam pressure is regulated using valves and checked with steam pressure gauges. The fuel system includes all equipment used to provide fuel to generate the necessary heat.



We are offering Industrial Oil And Gas Fired Steam Boiler.


Feature:

High workmanship.

Ease of maintenance.

Optimum heat transfer.

Great operational safety.

Space saving compact design.

Regular after sales service.



Intelligent Automation for Hassle-Free Operation

This diesel boiler is equipped with a comprehensive automation suite, including digital control panels and automatic electric ignition systems. Automatic water feeding and multi-level safety cut-offs simplify daily management and ensure protection from operational hazards. The digital interface allows users to monitor and control the boiler with minimal training, making it suitable for both new and experienced operators in demanding industrial settings.


Safety Engineered for Industrial Demands

Safety is paramount, with the system designed for multi-level protection. It comes with integrated pressure and temperature cut-off mechanisms, ensuring that the boiler shuts down automatically during irregular conditions. The robust construction, mineral wool insulation, and a minimum chimney height of 6 meters not only enhance safety but also help maintain optimal performance and efficiency throughout its 15-year lifespan.

FAQ's of Diesel boiler:


Q: How does the automatic electric ignition and control panel contribute to ease of use?

A: The automatic electric ignition system ensures safe and consistent start-ups without manual intervention, while the digital control panel allows operators to easily monitor and adjust operational parameters, significantly simplifying the management process for industrial users.

Q: What is the process for steam generation in this diesel boiler?

A: Diesel is combusted in the boiler's chamber to heat water, producing steam. The arc-welded mild steel construction, insulated with mineral wool, ensures effective heat transfer and energy efficiency, while built-in automation handles ignition and water feeding throughout the process.

Q: Where is this type of boiler typically installed and used?

A: This floor-mounted diesel boiler is commonly installed in industrial environments such as process plants, food production facilities, and chemical industries, where reliable steam generation is essential for manufacturing and processing operations.

Q: What are the benefits of using a multi-level safety system in the boiler?

A: The multi-level safety system, featuring pressure and temperature cut-off, reduces the risk of accidents by automatically shutting down the boiler during abnormal conditions, protecting both personnel and equipment, and ensuring operational reliability.

Q: When should the chimney height requirement be considered?

A: A minimum chimney height of 6 meters should be maintained during installation to ensure proper exhaust of combustion gases, compliance with safety regulations, and optimal boiler efficiency.

Q: What maintenance practices help achieve the expected 15-year lifespan?

A: Regular inspection of the insulation, safety systems, and fuel supply, along with periodic cleaning of the combustion chamber and control panel checks, are essential to maintain performance and achieve the boiler's designed lifespan.

Q: How does this boiler's fuel efficiency impact operational costs?

A: Operating at 85% heat efficiency and consuming 10-12 liters of diesel per hour, this boiler delivers more steam output for each unit of fuel, helping industrial users reduce overall fuel costs compared to less efficient models.